GO
+
Products
+
Temperature Humidity Chambers
Z Plus
MicroClimate Benchtop
MicroClimate 3 Compact
Stackable Benchtop Test Chamber
Remote Conditioner
Constant Climate Chambers
+
Thermal Shock Chambers
VTS Compact
VTS Large
TSB Liquid
Horizontal Thermal Shock
+
Stability Chambers
Stability Rooms
PharmaEvent Stability Chambers
Photostability Chambers
+
Walk-In Drive-In Chambers
Modular Walk In
Welded Walk In
Drive In Chambers
+
Vibration Test Chambers
Benchtop Vibration Table
HALT-HASS Chambers
AV Series
CV Series
Environmental Test Chambers
Industrial Freezers
Custom Designed Chambers
Controllers & Software
Industrial Ovens
Battery Test Chambers
Altitude Chambers
+
Industries
+
Pharmaceutical
Vaccine Freezers
Cold Chain Testing
Automotive
Electronics
Medical
Defense
Telecommunications
+
Energy
Battery
Solar
Gas & Oil
Other Industries
+
Customer Support
Upgrades
Preventive Maintenance
Calibration
Part Replacement & Returns
Startup & Training
+
Resources
News Center
Software & Manuals
Customer Training Seminars
White Papers
Industry Organizations & Consultants
Videos
Document Downloads
Careers
+
About
Why CSZ?
Services
+
Contact
Service Request
Locate Sales Rep
Directions
Product Request
English
Chinese
Korean
Spanish
Thai
Products
Temperature Humidity Chambers
Z Plus
MicroClimate Benchtop
MicroClimate 3 Compact
Stackable Benchtop Test Chamber
Remote Conditioner
Constant Climate Chambers
Walk-In Drive-In Chambers
Modular Walk In
Welded Walk In
Drive In Chambers
Industrial Freezers
Industrial Ovens
Thermal Shock Chambers
VTS Compact
VTS Large
TSB Liquid
Horizontal Thermal Shock
Vibration Test Chambers
Benchtop Vibration Table
HALT-HASS Chambers
AV Series
CV Series
Custom Designed Chambers
Battery Test Chambers
Stability Chambers
Stability Rooms
PharmaEvent Stability Chambers
Photostability Chambers
Environmental Test Chambers
Controllers & Software
Altitude Chambers
Industries
Pharmaceutical
Vaccine Freezers
Cold Chain Testing
Automotive
Electronics
Medical
Defense
Telecommunications
Energy
Battery
Solar
Gas & Oil
Other Industries
Customer Support
Upgrades
Preventive Maintenance
Calibration
Part Replacement & Returns
Startup & Training
Resources
News Center
Software & Manuals
Customer Training Seminars
White Papers
Industry Organizations & Consultants
Videos
Document Downloads
Careers
About
Why CSZ?
Services
Contact
Service Request
Locate Sales Rep
Directions
Product Request
GO
Products
>
Test Chamber Options
>
Environmental Chamber Options
Environmental Chamber Options
Listed below are the options that are available on CSZ Environmental Test Chambers.
Cabinet Options
Additional Access Ports
Additional circular, square, or rectangular ports are available in a variety of sizes. Ports may be placed on both sides of the chamber for ease of cable routing.
Glove Ports (CT-Series)
Two feed through ports, typically placed in chamber door, with protective gloves designed to reach in chamber and turn off/on test devices while chamber is in operation.
Cable Notch (CT-Series, RC-Series)
If routing cables through side ports is not an option for you, a cable notch may be placed in the front of your chamber.
Shelving
Optional product shelves are available for each CSZ chamber. Custom shelves and fixtures are also available.
Automatic Altitude Control (Altitude Models only)
Control valve enhances altitude control stability at various setpoints.
Humidity Options
Recirculating Humidity Water Supply
For customers that do not have a deionized water supply, we provide a recirculating water system that collects condensate from the chamber, stores it and then filters it in a reservoir for reuse.
Low Relative Humidity
For tests requiring humidity levels below 10% RH, we provide an optional low humidity system for testing down to 5% RH.
Humidity Demineralizer Water Filter System
Demineralizer removes water impurities and minerals that can harm your test chamber. Cartridges will turn orange-brown when used and are easily replaceable. Additional demineralizer cartridges are available for overnight delivery.
Water Pressure Regulator
Water pressure regulator is recommended to regulate incoming water supply to <=25 psig.
Reverse Osmosis Water System
Water purification system for use with city / tap water. This option is not needed if chamber has demineralizer filter system.
Instrumentation Options
Windows-Based Software Package
CSZ EZ-View software
is available for monitoring and controlling up to 20 chambers from any location.
Redundant Temperature Limit & Alarm
Provides essential failsafe over/under (hi/low) temperature protection for your valuable test items.
IEEE-488 Computer Interface
A parallel interface can be provided for interface with IEEE-488 parallel instrument control buss. A standard IEEE-488 connector is provided for easy connection to adjacent test equipment. This option is cannot be used in conjunction with RS-232/RS-485 communications.
Chart Recorders
A selection of one or two pen chart recorders are available with a variety of pre-printed charts or self printing thermal charts.
Running Time Meter
The optional run time meter includes a non-resettable display which will accumulate the system running time for routine maintenance and planning purposes.
Main Power Disconnect
Provides an additional level of safety by shutting down the main power to the chamber prior to maintenance or repair.
Customer Event Option (Digital Outputs)
Includes 15 event outputs with connection panel & removable plug connectors. Designed to turn customer’s electronic DUT’s (devices under test) ON or OFF at various stages of the customer programmed test profile. Each output may also be configured to perform other operations including alarm or profile status indicators.
Digital Input Option
Includes connection panel and 8 inputs that can be configured to perform various controller functions (i.e. start, hold, resume or terminate a profile, advance steps, control customer event outputs, etc.)
EZT Monitor Package
(provides 8 thermocouple / TC inputs through EZT-570i)
Designed to consist of eight (8) “T” type thermocouples (TC’s) for temperature readout with individual alarms, displays, and data logging for each input that can be monitored by the EZT-570i and the EZ-View software. The “black-box” unit itself will be mounted to the side or rear of the unit and the eight TC’s will pass through one of the existing side ports. These are TC’s only (no RH sensors or PT100-RTD’s) and are used for product temperature monitoring or temperature uniformity check within the chamber. (For monitoring only, no control.)
Optional F4 Controller
CSZ F4 Programmable Controller with Product Monitor, redundant high/low limit and EIA 232/485 Computer Interface. Replaces EZT-570i and mounts on a special fixture below the door.
Performance & Refrigeration Options
CO2/LN2 Boost Cooling
Boost cooling is available for applications that require a fast pulldown rate. An LN2 supply tank is required with a pressure of 25 psi (172 kpa).
CO2/LN2 Cooling Only (Direct Injection)
CO2/LN2 cooled chambers are available without mechanical refrigeration for lower initial costs on applications requiring ultra low temperatures down to -184°C (-300°F). An LN2 supply tank is required with a pressure of 25 psi.
Dry Air Purge System
A dry air purge system can be provided to reduce condensation within the chamber and on the test item during temperature cycling testing. This option is primarily used to prevent short circuits in electronic components and is also used for low humidity requirements.
Remote Refrigeration
Allows the testing chamber refrigeration system to be located approximately 50 linear feet away from the chamber. This option is commonly used for labs with space restrictions or to minimize noise levels.
Refrigeration Sound Deadening
Although CSZ chambers are quiet operating, sound foam is available as an option to further reduce the noise generated by the refrigeration system. This option is commonly used in larger horsepower chambers.